Product Showcase
+
  • 图片20(1778210594811).jpg

JH5V30A—256-Channel Cylindrical Soft-Pack Battery Capacity Grading and Testing Cabinet

▇ Independent single-point operation allows for customized charge and discharge settings for each channel, offering flexibility and convenience. ▇ Powerful software with a user-friendly human–machine interface. ▇ Four-wire output interface for high precision. ▇ Modular design for easy maintenance. ▇ Scan-to-start functionality for convenient operation and traceability.

Service Support:

  • Product Description
  • I. Technical Features

    ▇ Independent single-point operation allows for independent charge and discharge settings for each channel, offering flexibility and convenience.

    ▇ The software is powerful and features a user-friendly interface.

    ▇ Four-wire output interface, with high accuracy.

    ▇ Modular design concept, easy to maintain.

    ▇ Scan the code to start, making operation and traceability convenient.

     

    II. Main Technical Parameters:

    Serial number

    Specification Model

    JH5V30A-256CH

    1

    Number of output channels

    256CH

    2

    Communication method

    CAN/LAN network port

    3

    Testing method

    Compatible with (single-point/whole), QR code launch/click launch

    4

    Battery type

    Compatible with pouch and cylindrical battery testing

    5

    Charging voltage

    DC 0.1~5V

    6

    Discharge voltage

    DC 5–1.5 V

    7

    Charging current

    DC 0.1–30A

    8

    Discharge current

    DC 0.1–30A

    9

    Voltage accuracy

    ±(0.05%RD + 0.05%FS)

    10

    Current accuracy

    ±(0.05%RD + 0.05%FS)

    11

    Voltage resolution

    1mV

    12

    Voltage stability

    ≤0.1%

    13

    Current resolution

    1mA

    14

    Current stability

    ≤0.1%

    15

    Power output range

    0–38.4 W

    16

    Input impedance

    ≧10 MΩ

    17

    Input power supply

    AC 380V±10%/ 50Hz

    18

    Power accuracy

    ±(0.05%RD + 0.05%FS)

    19

    Energy feedback efficiency

    70%–85% (varies depending on battery capacity and associated cable losses)

    20

    Time setting range

    Set any value between 0 and 9,999 minutes; time units can be selected as h, min, or s, with a resolution of 1 second.

    21

    Temporal resolution

    1s

    22

    Recording method

    Charging record time, discharging record time, idle record time, global record time

    23

    Recording frequency

    1S~65535S

    24

    Charging mode

    Constant-current charging, constant-voltage charging, constant-current/constant-voltage (CC/CV), and constant-power charging.

    25

    Charging termination criteria

    Voltage, current, time, capacity

    26

    Discharge mode

    Constant-current discharge, constant-voltage discharge, constant-power discharge, constant-current/constant-voltage (CC/CV), and constant-resistance discharge.

    27

    Discharge cutoff conditions

    Voltage, current, time, capacity

    28

    Protection function

    Power input voltage protection: reverse polarity protection, overvoltage protection, overcurrent protection, and overtemperature protection.

    Data anomaly recovery;

    Battery reverse-connection protection function;

    4. The software provides protection against overvoltage, undervoltage, overcurrent, undercurrent, and overload; the setpoints for voltage and current protection are user‑adjustable, and the system can issue alerts and log events upon activation of these protections.

    29

    Number of single-cycle steps

    ≤9999, with nested loop functionality.

    30

    Continuous working hours

    The equipment’s power rating shall ensure that all channels can operate at full load continuously, 24/7, 365 days a year.

    31

    Equipment noise

    Less than 72 dB

    32

    Circuit structure

    Modular structural design, facilitating replacement and maintenance.

    33

    Connection method

    A pneumatic cylinder is used to press the cell together (with upper and lower probes connecting the cell’s positive and negative terminals), ensuring convenience and reliability.

    34

    Volume

    W2000*H1860*D750mm (Width*Height*Depth)

    35

    Weight

    Approximately 150 kg

    36

     

    Software

    1. The software supports various resumption modes, including manual pause‑resume, automatic resume upon software shutdown, resume after power loss, resume following a communication interruption, and resume after an abnormal stop.

    2. Supports barcode scanning, enabling the reading of both 1D and 2D barcodes, with options such as sequential scanning, skip‑channel scanning, and tray‑based scanning.

    3. Detailed local test data is stored, allowing you to view current and historical data for each channel at any time. Data can be displayed either as tabular values or as corresponding curves, and you can export the results as Excel reports individually or in batches. Additionally, you can configure the system to automatically export data upon test completion as needed.

    4. Supports capacity grading, enabling battery grade classification.

    5. Supports pass/fail judgment at the end of testing, determining Pass/NG results based on specified cycle capacity, voltage, time, and other parameters.

    6. Supports various step‑by‑step protections as well as global protection against voltage, current, and temperature abnormalities, with corresponding fault alarms.

    7. Supports unit conversion;

    8. Supports backend storage on the database server or integration with MES (optional);

    9. Supports MES system creation (optional);

    10. Offline software protection;

    11. The software offers free upgrades.

    37

    Operating/Storage Temperature

    -10℃~35℃/-20℃~60℃

    38

    Operating/Storage Ambient Relative Humidity

    ≤70% RH / ≤80% RH (no condensation)

    39

    Equipment maintenance

    Do not open the chassis if you are not a professional. Regularly inspect the device’s connectors to prevent poor contact.

    40

    Transportation

    The packaging is suitable for transportation by car, ship, aircraft, train, and other modes of transport. During transit, it should be protected from rain, and loading and unloading must be carried out in a careful and courteous manner.

Keywords: battery charge–discharge cabinet, lithium‑battery charge–discharge cabinet, sodium‑battery charge–discharge tester, solid‑state battery charge–discharge tester, lithium‑battery charge–discharge testing system, lithium‑battery charge–discharge tester, lithium‑battery capacity‑grading cabinet, power‑battery charge–discharge testing system, lithium‑battery pack charge–discharge testing system

Related products

Get a quote

Note: We will contact you within one business day. Please check your email.