JH5V50A-48CH Channel-Isolated Battery Charge/Discharge Test Cabinet
1. Single-point independence: Each channel can be configured with independent charge and discharge settings, offering flexibility and convenience. 2. Channel isolation: Each channel is electrically isolated from the others, with no shared ground; individual cells within a battery pack can be charged or discharged independently or in series‑parallel configurations. 3. Powerful software with a user-friendly human–machine interface. 4. Four-wire output interface for high measurement accuracy. 5. Modular design for easy maintenance. 6. Energy regeneration: Discharge energy is fed back to the grid, promoting energy efficiency and environmental protection. 7. Comprehensive protection features, including overvoltage, reverse polarity, overcurrent, short circuit, overheating, and cross‑connection (unintended parallel connections among series‑connected cells). 8. Channels can perform group‑level balancing as well as individual cell balancing. 9. Capable of testing the full range of lithium‑ion batteries—including lithium cobalt oxide, lithium manganese oxide, lithium iron phosphate, ternary materials (lithium nickel cobalt manganese oxide/lithium nickel cobalt aluminum oxide), and lithium titanate—as well as sodium‑ion batteries. 10. Scan‑code activation for convenient operation and traceability.
- Product Description
-
I. Technical Features
1. Single-point independence: independent charge and discharge settings can be configured for each channel, offering flexibility and convenience.
2. Channel isolation: Each channel is electrically isolated from the others and shares no common ground; individual cells within the battery pack can be charged and discharged independently or in series‑connected stacks.
3. The software is powerful and features a user-friendly human-machine interface.
4. Four-wire output interface with high accuracy.
5. Modular design for easy maintenance.
6. Energy regeneration: discharging energy back to the grid, promoting energy conservation and environmental protection.
7. Equipped with protection mechanisms against overvoltage, reverse polarity, overcurrent, short circuit, overheating, and cross‑connection (i.e., random串联 connections among individual cells in a battery pack).
8. Each channel can be configured for grouped equalization or independent equalization.
9. It can perform testing on the entire range of lithium‑ion batteries, including lithium cobalt oxide, lithium manganese oxide, lithium iron phosphate, ternary materials (lithium nickel‑cobalt‑manganese oxide/lithium nickel‑cobalt‑aluminum oxide), and lithium titanate, as well as sodium‑ion batteries.
10. Scan the code to start, making operation and traceability convenient.
II. Main Technical Parameters:
Serial number
Specification Model
JH5V50A-48CH
1
Number of output channels
48CH
2
Communication method
CAN/LAN network port
3
Output port and
Battery connection method
Tongkou
4
Testing method
Compatible with (single-point/whole), QR code launch/click launch
5
Charging voltage
DC 0.1~5V
6
Discharge voltage
DC 5–1.5 V
7
Charging current
DC 0.1–50 A
8
Discharge current
DC 0.1–50 A
9
Voltage accuracy
± 0.1%FS
10
Current accuracy
± 0.1%FS
11
Voltage resolution
1mV
12
Voltage stability
≤0.1%
13
Current resolution
1mA
14
Current stability
≤0.1%
15
Power output range
0–12 kW
16
Input impedance
≧10 MΩ
17
Input power supply
AC 380V±10%/ 50Hz
18
Power accuracy
± 0.1%FS
19
Energy feedback efficiency
70%–85% (varies depending on battery capacity and associated cable losses)
20
Time setting range
Set any value between 0 and 9,999 minutes; time units can be selected as h, min, or s, with a resolution of 1 second.
21
Temporal resolution
1s
22
Recording method
Charging record time, discharging record time, idle record time, global record time
23
Recording frequency
100mS~65535S
24
Charging mode
Constant-current charging, constant-voltage charging, constant-current/constant-voltage (CC/CV), and constant-power charging.
25
Charging termination criteria
Voltage, current, time, capacity
26
Discharge mode
Constant-current discharge, constant-voltage discharge, constant-power discharge, and constant-resistance discharge
27
Discharge cutoff conditions
Voltage, current, time, capacity
28
Protection function
Data anomaly recovery; reverse battery connection protection;
Software-based over‑voltage, under‑voltage, over‑current, under‑current, and over‑capacity protection; the voltage and current protection thresholds are user‑configurable, and the system provides alerts and logs upon activation of any protection.
29
Number of single-cycle steps
≤9999, with nested loop functionality
30
Continuous working hours
The equipment’s power rating shall ensure that all channels can operate at full load continuously, 24 hours a day.
31
Equipment noise
Less than 72 dB
32
Circuit structure
Modular structural design, facilitating replacement and maintenance.
33
Battery connection method
Alligator clip

34
Cabinet volume
W710*D800*H1860mm
35
Weight
Approximately 320 kg
36
Software
1. The software supports various resumption modes, including manual pause‑and‑resume, automatic resume upon software shutdown, resume after power loss, resume following a communication interruption, and resume after an abnormal stop.
2. Supports barcode scanning, enabling the reading of both 1D and 2D barcodes, with options such as sequential scanning, skip‑channel scanning, and tray‑based scanning.
3. Detailed test data is stored locally, allowing you to view current and historical data for each channel at any time. Data can be displayed either as tabular values or as corresponding curves, and you can export the data as Excel reports individually or in batches. Additionally, you can configure the system to automatically export the data upon test completion as needed.
4. Supports capacity grading, enabling battery grade classification.
5. Supports pass/fail judgment at the end of testing, determining Pass or NG results based on specified cycle capacity, voltage, time, and other parameters.
6. Supports various step‑by‑step protections as well as global protection against voltage, current, and temperature abnormalities, with corresponding fault alarms.
7. Supports unit conversion;
8. Supports backend storage on the database server or integration with the MES (optional);
9. Supports MES system creation (optional);
10. Offline software protection;
11. The software offers free upgrades.
37
Environmental engineering work
/Storage temperature
-10℃~30℃/-10℃~50℃
38
Operating/Storage Ambient Relative Humidity
≤70% RH / ≤80% RH (no condensation)
39
Equipment maintenance
Do not open the chassis if you are not a professional. Regularly inspect the device’s connectors to prevent poor contact.
40
Transportation
The packaging is suitable for transportation by car, ship, aircraft, train, and other modes; during transit, it should be protected from rain, and loading and unloading must be carried out in a careful and courteous manner.
Keywords: battery charge–discharge cabinet, lithium‑battery charge–discharge cabinet, sodium‑battery charge–discharge tester, solid‑state battery charge–discharge tester, lithium‑battery charge–discharge testing system, lithium‑battery charge–discharge tester, lithium‑battery capacity‑grading cabinet, power‑battery charge–discharge testing system, lithium‑battery pack charge–discharge testing system