Product Showcase
+
  • 截屏2026-05-23 15.03.45.png

JH60V30A-24CH Battery Charge–Discharge Test System – Technical Specification Sheet

▇ Independent single-point operation allows for customized charge and discharge settings for each channel, offering flexibility and convenience. ▇ Powerful software with a user-friendly human–machine interface. ▇ Four-wire output interface for high accuracy. ▇ Modular design for easy maintenance. ▇ Energy regeneration: discharging energy back to the grid, promoting energy efficiency and environmental protection. ▇ Scan-to-start functionality for simplified operation and traceability.

Service Support:

  • Product Description
  • I. Technical Features

    ▇ Independent single-point operation allows for independent charge and discharge settings for each channel, offering flexibility and convenience.

    ▇ The software is powerful and features a user-friendly interface.

    ▇ Four-wire output interface, with high accuracy.

    ▇ Modular design concept, easy to maintain.

    ▇ Energy regeneration: discharging energy back to the grid; energy-saving and environmentally friendly.

    ▇ Scan the code to start, making operation and traceability convenient.

     

    II. Main Technical Parameters:

    Serial number Specification and Model JH60V30A-24CH
    1 Number of output channels 24CH
    2 Communication method CAN/LAN network port
    3

    Output port and

    Battery connection method

    Same mouth / Different mouth
    4 Testing method Compatible with (single-point/whole), QR code launch/click launch
    5 Charging voltage DC 0.1~60V
    6 Discharge voltage DC 60–1.5 V
    7 Charging current DC 0.1–30 A
    8 Discharge current DC 0.1–30 A
    9 Voltage accuracy ±(0.05%RD + 0.05%FS)
    10 Current accuracy ±(0.05%RD + 0.05%FS)
    11 Voltage resolution 1mV
    12 Voltage stability ≤0.1%
    13 Current resolution 1mA
    14 Current stability ≤0.1%
    15 Current startup response time <50ms
    16 Power output range 0–43.2 kW
    17 Input impedance ≧10 MΩ
    18 Input power supply AC 380V±10%/ 50Hz
    19 Power accuracy ±(0.05%RD + 0.05%FS)
    20 Energy Regeneration Efficiency 70%–90% (varies depending on battery capacity and associated cable losses)
    21 Time setting range Set any value between 0 and 9,999 minutes; time units can be selected as h, min, or s, with a resolution of s or ms.
    22 Temporal resolution 100ms
    23 Recording method Charging record time, discharging record time, idle record time, global record time
    24 Recording frequency 100mS~65535S
    25 Charging mode Constant-current charging, constant-voltage charging, constant-current/constant-voltage (CC/CV), and constant-power charging.
    26 Charging termination conditions Voltage, current, time, capacity, temperature (options)
    27 Discharge mode Constant-current discharge, constant-voltage discharge, constant-power discharge, and constant-resistance discharge
    28 Discharge cutoff conditions Voltage, current, time, capacity, temperature (options)
    29

    Temperature Acquisition

    (Options)

    Temperature: -40℃ to 150℃ Accuracy: 0.1℃ Resolution: 0.1℃
    30

    BMS Communication

    (Option) (Battery Management System Link)

    BMS total voltage, BMS total current
    BMS cell voltage, BMS cell voltage difference
    BMS cell temperature, BMS cell temperature difference
    BMS temperature, BMS SOC
    31 Protection function

    Data anomaly recovery; reverse battery connection protection;

    Software-based over‑voltage, under‑voltage, over‑current, under‑current, and over‑capacity protection; the voltage and current protection thresholds are user‑configurable, and the system provides alerts and logs upon activation.

    32 Number of single-cycle steps ≤9999, with nested loop functionality
    33 Continuous working hours The equipment’s power rating shall ensure that all channels can operate at full load continuously, 24/7, 365 days a year.
    34 Equipment noise Less than 70 dB
    35 Protection rating IP20
    36 Circuit structure Modular structural design, facilitating replacement and maintenance.
    37

     

    Battery connection method

    (Copper nose or alligator clip

    Choose one of two)

    38 Volume W710*D850*H1930mm
    39 Weight Approximately 300 kg
    40

     

    Software

    1. The software supports various resumption modes, including manual pause‑and‑resume, automatic resume upon software shutdown, resume after power loss, resume following a communication interruption, and resume after an abnormal stop.

    2. Supports barcode scanning, enabling the reading of both 1D and 2D barcodes, with options such as sequential scanning, skip‑channel scanning, and tray‑based scanning.

    3. Detailed test data is stored locally, allowing you to view current and historical data for each channel at any time. Data can be displayed either as tabular values or as corresponding curves, and you can export the data as Excel reports individually or in batches. Additionally, you can configure the system to automatically export data upon test completion as needed.

    4. Supports capacity grading, enabling battery grade classification.

    5. Supports pass/fail judgment at the end of testing, determining Pass/NG results based on specified cycle capacity, voltage, time, and other parameters.

    6. Supports various step‑by‑step protections as well as global protection against voltage, current, and temperature abnormalities, with corresponding fault alarms.

    7. Supports unit conversion;

    8. Supports backend storage on the database server or integration with the MES (optional);

    9. Supports MES system creation (optional);

    10. Offline software protection;

    11. The software offers free upgrades.

    41 Operating/Storage Temperature -10℃ to 35℃ / -20℃ to 60℃
    42 Operating/Storage Ambient Relative Humidity ≤70% RH / ≤80% RH (no condensation)
    43 Equipment maintenance Do not open the chassis if you are not a professional. Regularly inspect the device’s connectors to prevent poor contact.
    44 Transportation The packaging is suitable for transportation by car, ship, aircraft, train, and other modes; during transit, it should be protected from rain, and loading and unloading must be carried out in a careful and respectful manner.

     

     

     

Keywords: battery charge–discharge cabinet, lithium‑battery charge–discharge cabinet, sodium‑battery charge–discharge tester, solid‑state battery charge–discharge tester, lithium‑battery charge–discharge testing system, lithium‑battery charge–discharge tester, lithium‑battery capacity‑grading cabinet, power‑battery charge–discharge testing system, lithium‑battery pack charge–discharge testing system

Related products

Get a quote

Note: We will contact you within one business day. Please check your email.

Security verification