JH60V10A-64CH Battery Charge–Discharge Test System – Technical Specification
I. Technical Features ▇ Single-point independence: Each channel can be configured with independent charge and discharge settings, offering flexibility and convenience. ▇ Powerful software with a user-friendly interface. ▇ Four-wire output interface for high accuracy. ▇ Modular design for easy maintenance. ▇ Energy feedback: Discharge energy is fed back to the grid, promoting energy conservation and environmental protection. ▇ Scan‑code activation for convenient operation and traceability. II. Main Technical Parameters: | No. | Specification/Model | JH60V10A-64CH1 | | --- | --------------------- | ---------------- | | 1 | Number of Output Channels | 64 CH | | 2 | Communication Method | CAN/LAN, Ethernet | | 3 | Battery Connection Type | Same port | | 4 | Test Mode Compatibility | Single‑point/Full‑system, scan‑code start/click start | | 5 | Charging Voltage | DC 0.1–60 V | | 6 | Discharging Voltage | DC 60–2.0 V | | 7 | Charging Current | DC 0.1–10 A | | 8 | Discharging Current | DC 0.1–10 A | | 9 | Voltage Accuracy | ±(0.05% RD + 0.05% FS) | | 10 | Current Accuracy | ±(0.05% RD + 0.05% FS) | | 11 | Voltage Resolution | 1 mV | | 12 | Voltage Stability | ≤0.1% | | 13 | Current Resolution | 1 mA | | 14 | Current Stability | ≤0.1% | | 15 | Current Startup Response Time | <50 ms | | 16 | Power Output Range | 0–38.4 kW | | 17 | Input Impedance | ≥10 MΩ | | 18 | Input Power Supply | AC 380 V ±10%, 50 Hz | | 19 | Power Accuracy | ±(0.05% RD + 0.05% FS) | | 20 | Energy Feedback Efficiency | 65%–90% (varies with battery capacity and cable losses) | | 21 | Time Setting Range | 0–9,999 minutes; units: h, min, s; resolution: s, ms | | 22 | Time Resolution | 100 ms | | 23 | Recording Modes | Charge time, discharge time, idle time, global record time | | 24 | Recording Frequency | 100 ms–65,535 s | | 25 | Charging Modes | Constant current, constant voltage, CC/CV, constant power | | 26 | Charging Termination Conditions | Voltage, current, time, capacity | | 27 | Discharging Modes | Constant current, constant voltage, constant power, constant resistance | | 28 | Discharging Termination Conditions | Voltage, current, time, capacity | | 29 | Protection Functions | Data anomaly recovery; reverse polarity protection; over‑voltage, under‑voltage, over‑current, under‑current, and over‑capacity protections—adjustable thresholds with alerts and logging | | 30 | Single Cycle Steps | ≤9,999 steps, with nested loop capability | | 31 | Continuous Operation | Equipment must sustain full‑load operation across all channels, 24/7, 365 days a year | | 32 | Noise Level | <70 dB | | 33 | Protection Rating | IP20 | | 34 | Circuit Structure | Modular design for easy replacement and maintenance | | 35 | Battery Connection Method | Copper lugs or alligator clips (choose one) | | 36 | Physical Dimensions | W710 × D850 × H1930 mm | | 37 | Weight | ~300 kg | | 38 | Software Features | 1. Supports various resume functions: manual pause/resume, software shutdown/resume, power outage interruption/resume, device communication disruption/resume, abnormal stop/resume; 2. Barcode scanning: supports 1D and 2D codes, with sequential scanning, channel‑hopping scanning, tray‑loading scanning, etc.; 3. Local test data storage: view real‑time and historical data per channel, with dual presentation options—data vs. curves—and export in EXCEL format individually or in batches; automatic data export upon test completion configurable as needed; 4. Capacity sorting: classifies batteries by grade; 5. Pass/NG judgment at test completion based on specified cycle parameters such as capacity, voltage, and time; 6. Comprehensive step‑level and global protection against voltage, current, and temperature anomalies, with alarm notifications; 7. Unit conversion support; 8. Backend database storage or MES integration (optional); 9. MES system creation (optional); 10. Offline protection; 11. Free software upgrades. III. Detailed Configuration 1. Exterior Color & Cabinet: RL7035 industrial gray. 2. Packing List: | No. | Item Name | Brand | Quantity | | --- | ----------------------- | ------------- | -------- | | 1 | Main Cabinet | Domestic Jinghui | 1 unit | | 2 | Industrial PC + 19‑inch Monitor | Domestic Hangjia | 1 set | | 3 | Testing Software | Domestic Jinghui | 1 set | | 4 | Test Connection Cables | Domestic Jinghui | 64 sets | | 5 | Factory Inspection Report | Domestic Jinghui | 1 copy | | 6 | User Manual | Domestic Jinghui | 1 copy | | 7 | Product Certificate/Warranty Card | Domestic Jinghui | 1 copy |
- Product Description
-
I. Technical Features
▇ Single Point independence, which can be tailored to each Channel Configure independent charge and discharge settings for flexibility and convenience.
▇ The software is powerful and features a user-friendly human-machine interface.
▇ Four-wire output interface with high accuracy.
▇ Modular design for easy maintenance.
▇ Energy Feedback , Discharge energy is fed back into the grid, promoting energy conservation and environmental protection.
▇ Scan to Launch , Easy to operate and traceable 。
II. Main Technical Parameters:
Serial number
Specification Model
JH60V10A-64CH
1
Number of output channels
64CH
2
Communication method
CAN/LAN network port
3
Output port and
Battery connection method
Same mouth
4
Testing method
Compatible with (single-point/whole), QR code launch/click launch
5
Charging voltage
DC 0.1~60V
6
Discharge voltage
DC 60~2.0V
7
Charging current
DC 0.1~10A
8
Discharge current
DC 0.1~10A
9
Voltage accuracy
±(0.05%RD + 0.05%FS)
10
Current accuracy
±(0.05%RD + 0.05%FS)
11
Voltage resolution
1mV
12
Voltage stability
≤0.1%
13
Current resolution
1mA
14
Current stability
≤0.1%
15
Current startup response time
<50ms
16
Power output range
0–38.4 kW
17
Input impedance
≧10 MΩ
18
Input power supply
AC 380V±10%/ 50Hz
19
Power accuracy
±(0.05%RD + 0.05%FS)
20
Energy feedback efficiency
65%–90% (varies depending on battery capacity and associated cable losses)
21
Time setting range
Set any value between 0 and 9,999 minutes; time units can be selected as h, min, or s, with a resolution of s or ms.
22
Temporal resolution
100ms
23
Recording method
Charging record time, discharging record time, idle record time, global record time
24
Recording frequency
100mS~65535S
25
Charging mode
Constant-current charging, constant-voltage charging, constant-current/constant-voltage (CC/CV), and constant-power charging.
26
Charging termination conditions
Voltage, current, time, capacity
27
Discharge mode
Constant-current discharge, constant-voltage discharge, constant-power discharge, and constant-resistance discharge
28
Discharge cutoff conditions
Voltage, current, time, capacity
29
Protection function
Data anomaly recovery; reverse battery connection protection;
Software-based over‑voltage, under‑voltage, over‑current, under‑current, and over‑capacity protection; the voltage and current protection thresholds are user‑adjustable, and the system provides alerts and logs upon activation of any protection function.
30
Number of single-cycle steps
≤9999, with nested loop functionality
31
Continuous working hours
The equipment’s power rating shall ensure that all channels can operate at full load continuously, 24/7, 365 days a year.
32
Equipment noise
Less than 70 dB
33
Protection rating
IP20
34
Circuit structure
Modular structural design, facilitating replacement and maintenance.
35
Battery connection method
(Copper nose or alligator clip
Choose one of two)


36
Volume
W710*D850*H1930mm
37
Weight
Approximately 300 kg
38
Software
1. The software supports various resumption modes, including manual pause‑and‑resume, automatic resume upon software shutdown, resume after power loss, resume following a communication interruption, and resume after an abnormal stop.
2. Supports barcode scanning, enabling the reading of both 1D and 2D barcodes, with options such as sequential scanning, skip‑channel scanning, and tray‑based scanning.
3. Detailed test data is stored locally, allowing you to view current and historical data for each channel at any time. Data can be displayed either as tabular values or as corresponding curves, and you can export the data as Excel reports individually or in batches. Additionally, you can configure the system to automatically export the data upon test completion, as needed.
4. Supports capacity grading, enabling battery grade classification.
5. Supports pass/fail judgment at the end of testing, determining Pass/NG results based on specified parameters such as cycle capacity, voltage, and time.
6. Supports various step‑by‑step protections as well as global protection against voltage, current, and temperature abnormalities, with corresponding fault alarms.
7. Supports unit conversion;
8. Supports backend storage on the database server or integration with the MES (optional);
9. Supports MES system creation (optional);
10. Offline software protection;
11. The software offers free upgrades.
39
Operating/Storage Temperature
-10℃ to 35℃ / -20℃ to 60℃
40
Operating/Storage Ambient Relative Humidity
≤70% RH / ≤80% RH (no condensation)
41
Equipment maintenance
Do not open the chassis unless you are a qualified professional. Regularly inspect the device’s connectors to prevent poor contact.
42
Transportation
The packaging is suitable for transportation by car, ship, aircraft, train, and other modes; during transit, it should be protected from rain, and loading and unloading must be carried out in a careful and courteous manner.
Keywords: battery charge–discharge cabinet, lithium‑battery charge–discharge cabinet, sodium‑battery charge–discharge tester, solid‑state battery charge–discharge tester, lithium‑battery charge–discharge testing system, lithium‑battery charge–discharge tester, lithium‑battery capacity‑grading cabinet, power‑battery charge–discharge testing system, lithium‑battery pack charge–discharge testing system
Related products
Get a quote